Application
- Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures.
- Provides protection where equipment may be hosed down or otherwise be very wet, or in outdoor applications for full weather protection.
Standards
- UL 508A Type 3R, 4, 12 and 13
- CSA Type 3R, 4, 12 and 13
- Complies with
- NEMA Type 3R, 4, 12 and 13
- IEC 60529, IP66
Construction
- Body formed from 16 or 14 gauge steel. Covers are formed from 14 gauge steel.
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Welded brackets provide for enclosure mounting.
- Continuous hinged cover is secured with stainless steel clamps and screws.
- Stainless steel continuous hinge on door may be removed by pulling the stainless steel hinge pin.
- Seamless poured-in place gasket.
- Internal threaded weld studs are provided for mounting inner panels.
- A bonding stud is provided on the door and a grounding stud is provided in the enclosure.
Finish
- Cover and enclosure are phosphatized, finished in recoatable smooth ANSI 61 gray powder coating.
Accessories
- Additional Inner Panels
- Terminal Kit Assemblies
- Swing Panel Kit
- Door Clamping Hardware
- Junction Box Quick Release Clamp
- Junction Box Padlock Kit
- Climate Control
- General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure | Optional Mounting Panel | |||||
---|---|---|---|---|---|---|
Part No. | H | W | D | Part No. | H | W |
HJ443HLP | 4.00 | 4.00 | 3.00 | - | - | - |
HJ643HLP | 6.00 | 4.00 | 3.00 | 14R0503 | 4.88 | 2.88 |
HJ863HLP | 8.00 | 6.00 | 3.50 | 14R0705 | 6.75 | 4.88 |
HJ683HLP | 6.00 | 8.00 | 3.50 | 14R0705 | 6.75 | 4.88 |
HJ444HLP | 4.00 | 4.00 | 4.00 | - | - | - |
HJ644HLP | 6.00 | 4.00 | 4.00 | 14R0503 | 4.88 | 2.88 |
HJ664HLP | 6.00 | 6.00 | 4.00 | 14R0505 | 4.88 | 4.88 |
HJ884HLP | 8.00 | 8.00 | 4.00 | 14R0707 | 6.75 | 6.88 |
HJ1084HLP | 10.00 | 8.00 | 4.00 | 14R0907 | 8.75 | 6.88 |
HJ8104HLP | 8.00 | 10.00 | 4.00 | 14R0907 | 8.75 | 6.88 |
HJ1264HLP | 12.00 | 6.00 | 4.00 | 14R1105 | 10.75 | 4.88 |
HJ12105HLP | 12.00 | 10.00 | 5.00 | 14R1109 | 10.75 | 8.88 |
HJ10125HLP | 10.00 | 12.00 | 5.00 | 14R1109 | 10.75 | 8.88 |
HJ866HLP | 8.00 | 6.00 | 6.00 | 14R0705 | 6.75 | 4.88 |
HJ1086HLP | 10.00 | 8.00 | 6.00 | 14R0907 | 8.75 | 6.88 |
HJ10106HLP | 10.00 | 10.00 | 6.00 | 14R0909 | 8.75 | 8.88 |
HJ12126HLP | 12.00 | 12.00 | 6.00 | 14R1111 | 10.75 | 10.88 |
HJ1486HLP | 14.00 | 8.00 | 6.00 | 14R1307 | 12.75 | 6.88 |
HJ14126HLP | 14.00 | 12.00 | 6.00 | 14R1311 | 12.75 | 10.88 |
HJ12146HLP | 12.00 | 14.00 | 6.00 | 14R1311 | 12.75 | 10.88 |
HJ16106HLP | 16.00 | 10.00 | 6.00 | 14R1509 | 14.75 | 8.88 |
HJ16146HLP | 16.00 | 14.00 | 6.00 | 14R1513 | 14.75 | 12.88 |
HJ14166HLP | 14.00 | 16.00 | 6.00 | 14R1513 | 14.75 | 12.88 |
HJ12108HLP | 12.00 | 10.00 | 8.00 | 14R1109 | 10.75 | 8.88 |
HJ14128HLP | 14.00 | 12.00 | 8.00 | 14R1311 | 12.75 | 10.88 |
HJ16148HLP | 16.00 | 14.00 | 8.00 | 14R1513 | 14.75 | 12.88 |
HJ161410HLP | 16.00 | 14.00 | 10.00 | 14R1513 | 14.75 | 12.88 |